LC1D65008M7 – Schneider Electric TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 <= 440 V 80 A 220 V AC 50/60 Hz coil — SCHNEIDER

Product image for reference. Check the manufacturer's documentation for exact appearance and dimensions.

SCHNEIDER

LC1D65008M7 – Schneider Electric TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 <= 440 V 80 A 220 V AC 50/60 Hz coil

Brand
SCHNEIDER
Model / part no.
LC1D65008M7
Category
Contactors
In stock in Dubai. Price on request. Our team confirms price and quantity with every quotation.

TeSys Deca contactor, 4 poles (2NO/2NC),for load control applications in category AC-1. and for non-inductive load control applications up to 80A@60℃. It provides a 220V 50/60Hz standard AC coil,without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Very compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN), Green Premium compliant (RoHS/REACh).

Specifications Source: Schneider Electric product page
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltage
  • Power circuit: <= 690 V AC 25...400 Hz
  • Power circuit: <= 300 V DC
[Ie] rated operational current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Compatibility codeLC1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current80 A (at 60 °C) for power circuit
Irms rated making capacity1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
  • 640 A 40 °C - 10 s for power circuit
  • 900 A 40 °C - 1 s for power circuit
  • 110 A 40 °C - 10 min for power circuit
  • 260 A 40 °C - 1 min for power circuit
Associated fuse rating
  • 125 A gG at <= 690 V coordination type 1 for power circuit
  • 125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole9.6 W AC-1
[Ui] rated insulation voltage
  • Power circuit: 600 V CSA certified
  • Power circuit: 600 V UL certified
  • Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability level
  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 80 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits
  • 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
  • 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
  • 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
  • 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA
  • 140 VA 60 Hz cos phi 0.75 (at 20 °C)
  • 160 VA 50 Hz cos phi 0.75 (at 20 °C)

Questions about this product? Call +971 4 263 0773 or email info@universemiddleeast.com.