CAD32P7 – SCHNEIDER TeSys D control relay – 3 NO + 2 NC – <= 690 V – 230 V AC standard coil — SCHNEIDER

Product image for reference. Check the manufacturer's documentation for exact appearance and dimensions.

SCHNEIDER

CAD32P7 – SCHNEIDER TeSys D control relay – 3 NO + 2 NC – <= 690 V – 230 V AC standard coil

Brand
SCHNEIDER
Model / part no.
CAD32P7
Category
Switches & Relays
Type
Control Relays & Sockets
In stock in Dubai. Price on request. Our team confirms price and quantity with every quotation.
Specifications
Product NameTeSys CAD
BrandSchneider Electric
SeriesTeSys / TeSys Deca
TypeControl Relay
Device Short NameCAD
Contactor ApplicationControl Circuit
Utilisation CategoryAC-14, AC-15, DC-13
Pole Contact Composition3 NO + 2 NC
Rated Operational Voltage ([Ue])≤ 690 V AC, 25…400 Hz
Control Circuit TypeAC at 50/60 Hz
Control Circuit Voltage ([Uc])230 V AC, 50/60 Hz
Impulse Withstand Voltage ([Uimp])6 kV (IEC 60947)
Rated Thermal Current ([Ith])10 A (at 60 °C)
Rated Making Capacity (Irms)
  • 140 A AC (IEC 60947-5-1)
  • 250 A DC (IEC 60947-5-1)
Rated Short-Time Withstand Current ([Icw])
  • 100 A – 1 s
  • 120 A – 500 ms
  • 140 A – 100 ms
Associated Fuse Rating10 A gG (IEC 60947-5-1)
Rated Insulation Voltage ([Ui])
  • 690 V (IEC 60947-5-1)
  • 600 V (UL / CSA certified)
Mounting SupportRail, Plate
Connections – Terminals
  • 1× flexible 1…4 mm² (with/without cable end)
  • 2× flexible 1…4 mm² (without cable end)
  • 2× flexible 1…2.5 mm² (with cable end)
  • 1× solid 1…4 mm² (without cable end)
  • 2× solid 1…4 mm² (without cable end)
Tightening Torque1.2 N·m (Philips No 2 / Flat Ø 6 mm / Pozidriv No 2)
Drop-out0.3…0.6 Uc (-40…70 °C)
Operational
  • 0.8…1.1 Uc (AC 50 Hz, -40…60 °C)
  • 0.85…1.1 Uc (AC 60 Hz, -40…60 °C)
  • 1…1.1 Uc (AC 50/60 Hz, 60…70 °C)
Operating Time
  • 12–22 ms (NO closing)
  • 4–12 ms (NO opening)
  • 4–19 ms (NC opening)
  • 6–17 ms (NC closing)
Mechanical Durability30 million cycles
Maximum Operating Rate180 cycles/min
Inrush Power70 VA (50 Hz, at 20 °C)
Hold-in Power Consumption8 VA (50 Hz, at 20 °C)
Minimum Switching Voltage17 V
Minimum Switching Current5 mA
Non-Overlap Time1.5 ms (energisation & de-energisation between NC and NO)
Insulation Resistance> 10 MΩ
Shocks (open)10 Gn, 11 ms (IEC 60068-2-27)
Shocks (closed)15 Gn, 11 ms (IEC 60068-2-27)
Vibrations (open)2 Gn, 5–300 Hz (IEC 60068-2-6)
Vibrations (closed)4 Gn, 5–300 Hz (IEC 60068-2-6)
Dimensions (HxWxD)77 x 45 x 84 mm
Net Weight0.58 kg
Standards
  • EN/IEC 60947-5-1
  • GB/T 14048.5
  • UL 60947-5-1
  • CSA C22.2 No 60947-5-1
  • JIS C8201-5-1
CertificationsCB, CCC, UL, CSA, EAC, CE, UKCA
IP Degree of ProtectionIP2X (front face, VDE 0106)
Protective TreatmentTH (IEC 60068)
Operating Temperature-40 to +60 °C (up to 70 °C with derating)
Storage Temperature-60 to +80 °C
Operating Altitude0…3000 m

Questions about this product? Call +971 4 263 0773 or email info@universemiddleeast.com.