TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides 110V 50/60Hz AC coils, 2NO built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Specifications Source: Schneider Electric product page
Product or component typeReversing contactor
Device short nameLC2K
Device applicationControl
Contactor application
  • Resistive load
  • Motor control
Utilisation category
  • AC-3
  • AC-3e
  • AC-4
  • AC-1
Device presentationPreassembled with reversing power busbar
Poles description3P
Power pole contact composition3 NO
[Ue] rated operational voltage
  • Power circuit: 690 V AC 50/60 Hz
  • Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current
  • 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
  • 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Motor power kW
  • 2.2 kW at 220...230 V AC 50/60 Hz
  • 4 kW at 380...415 V AC 50/60 Hz
  • 4 kW at 440/690 V AC 50/60 Hz
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current
  • 20 A (at 60 °C) for power circuit
  • 10 A (at 50 °C) for signalling circuit
Irms rated making capacity
  • 110 A AC for power circuit conforming to IEC 60947
  • 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity
  • 110 A at 220...230 V conforming to IEC 60947
  • 110 A at 380...400 V conforming to IEC 60947
  • 110 A at 415 V conforming to IEC 60947
  • 110 A at 440 V conforming to IEC 60947
  • 80 A at 500 V conforming to IEC 60947
  • 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current
  • 90 A 50 °C - 1 s for power circuit
  • 85 A 50 °C - 5 s for power circuit
  • 80 A 50 °C - 10 s for power circuit
  • 60 A 50 °C - 30 s for power circuit
  • 45 A 50 °C - 1 min for power circuit
  • 40 A 50 °C - 3 min for power circuit
  • 20 A 50 °C - >= 15 min for power circuit
  • 80 A - 1 s for signalling circuit
  • 90 A - 500 ms for signalling circuit
  • 110 A - 100 ms for signalling circuit
Associated fuse rating
  • 25 A gG at <= 440 V for power circuit
  • 25 A aM for power circuit
  • 10 A gG for signalling circuit conforming to IEC 60947
  • 10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage
  • Power circuit: 600 V conforming to UL 508
  • Power circuit: 690 V conforming to IEC 60947-4-1
  • Signalling circuit: 690 V conforming to IEC 60947-4-1
  • Signalling circuit: 690 V conforming to IEC 60947-5-1
  • Signalling circuit: 600 V conforming to UL 508
  • Power circuit: 600 V conforming to CSA C22.2 No 14
  • Signalling circuit: 600 V conforming to CSA C22.2 No 14
Electrical durability
  • 1.3 Mcycles 9 A AC-3 at Ue <= 440 V
  • 1.3 Mcycles 9 A AC-3e at Ue <= 440 V
  • 0.16 Mcycles 20 A AC-1 at Ue <= 690 V
  • 0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Interlocking typeMechanical
Mounting support
  • Rail
  • Plate
Standards
  • EN/IEC 60947-4-1
  • GB/T 14048.4
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • JIS C8201-4-1
Product certifications
  • CB Scheme
  • CCC
  • UL
  • CSA
  • EAC
  • CE
  • UKCA
Connections - terminals
  • Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
  • Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
  • Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
  • Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
  • Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
  • Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque
  • 0.8…1.3 N.m - on screw clamp terminals Philips No 2
  • 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
  • 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2