GV2ME16 – SCHNEIDER Motor circuit breaker, TeSys GV2, 3P, 9-14 A
-
Product Type: Motor circuit breaker
-
Device Short Name: GV2ME
-
Device Application: Motor protection
-
Trip Unit Technology: Thermal-magnetic
-
Poles: 3P
-
Network Type: AC
-
Utilization Category:
-
Category A (IEC 60947-2)
-
AC-3, AC-3e (IEC 60947-4-1)
-
-
Network Frequency: 50/60 Hz (IEC 60947-2)
-
Motor Power (kW):
-
5.5 kW at 400/415 V AC 50/60 Hz
-
7.5 kW at 500 V AC 50/60 Hz
-
9 kW at 690 V AC 50/60 Hz
-
11 kW at 690 V AC 50/60 Hz
-
-
Breaking Capacity:
-
100 kA Icu at 230/240 V AC 50/60 Hz (IEC 60947-2)
-
15 kA Icu at 400/415 V AC 50/60 Hz (IEC 60947-2)
-
8 kA Icu at 440 V AC 50/60 Hz (IEC 60947-2)
-
6 kA Icu at 500 V AC 50/60 Hz (IEC 60947-2)
-
3 kA Icu at 690 V AC 50/60 Hz (IEC 60947-2)
-
-
Rated Service Short-Circuit Breaking Capacity (Ics):
-
100% at 230/240 V AC 50/60 Hz (IEC 60947-2)
-
50% at 400/415 V and 440 V AC 50/60 Hz (IEC 60947-2)
-
75% at 500 V and 690 V AC 50/60 Hz (IEC 60947-2)
-
-
Control Type: Push-button
-
Rated Current (In): 14 A
-
Thermal Protection Adjustment Range: 9–14 A (IEC 60947-2)
-
Magnetic Tripping Current: 253.4 A
-
Conventional Free Air Thermal Current (Ith): 14 A (IEC 60947-2)
-
Rated Operational Voltage (Ue): 690 V AC 50/60 Hz (IEC 60947-2)
-
Rated Insulation Voltage (Ui): 690 V AC 50/60 Hz (IEC 60947-2)
-
Rated Impulse Withstand Voltage (Uimp): 6 kV (IEC 60947-2)
-
Phase Failure Sensitivity: Yes (IEC 60947-4-1)
-
Suitability for Isolation: Yes (IEC 60947-1)
-
Power Dissipation per Pole: 2.5 W
-
Mechanical Durability: 100000 cycles
-
Electrical Durability: 100000 cycles for AC-3, AC-3e at 415 V
-
Rated Duty: Uninterrupted (IEC 60947-4-1)
-
Connections – Terminals:
-
Power circuit: Screw clamp terminal 2 cable(s) 1–6 mm² solid
-
Power circuit: Screw clamp terminal 2 cable(s) 1.5–6 mm² flexible without cable end
-
Power circuit: Screw clamp terminal 2 cable(s) 1–4 mm² flexible with cable end
-
-
Tightening Torque: 1.7 N.m on screw clamp terminal
-
Fixing Mode: 35 mm symmetrical DIN rail (clipped), Panel (screwed with adaptor plate)
-
Mounting Position: Horizontal, Vertical
-
Dimensions: 89 mm (H) x 45 mm (W) x 78.5 mm (D)
-
Weight: 0.26 kg
-
Colour: Dark grey
-
Standards:
-
EN/IEC 60947-2
-
EN/IEC 60947-4-1
-
UL 60947-4-1
-
CSA C22.2 No 60947-4-1
-
IEC/EN 60335-2-40:Annex JJ
-
IEC/EN 60335-1:Clause 30.2
-
-
Certifications: CCC, UL, CSA, EAC, ATEX, LROS (Lloyds register of shipping), BV, RINA, DNV-GL, UKCA
-
IK Degree of Protection: IK04
-
IP Degree of Protection: IP20 (IEC 60529)
-
Climatic Withstand: IACS E10 (damp heat)
-
Ambient Air Temperature for Operation: -20 to 60 °C
-
Ambient Air Temperature for Storage: -40 to 80 °C
-
Fire Resistance: 960 °C (IEC 60695-2-11)
-
Mechanical Robustness:
-
Shocks: 30 Gn for 11 ms
-
Vibrations: 5 Gn, 5-150 Hz
-
-
Operating Altitude: ≤2000 m
Description
-
Product Type: Motor circuit breaker
-
Device Short Name: GV2ME
-
Device Application: Motor protection
-
Trip Unit Technology: Thermal-magnetic
-
Poles: 3P
-
Network Type: AC
-
Utilization Category:
-
Category A (IEC 60947-2)
-
AC-3, AC-3e (IEC 60947-4-1)
-
-
Network Frequency: 50/60 Hz (IEC 60947-2)
-
Motor Power (kW):
-
5.5 kW at 400/415 V AC 50/60 Hz
-
7.5 kW at 500 V AC 50/60 Hz
-
9 kW at 690 V AC 50/60 Hz
-
11 kW at 690 V AC 50/60 Hz
-
-
Breaking Capacity:
-
100 kA Icu at 230/240 V AC 50/60 Hz (IEC 60947-2)
-
15 kA Icu at 400/415 V AC 50/60 Hz (IEC 60947-2)
-
8 kA Icu at 440 V AC 50/60 Hz (IEC 60947-2)
-
6 kA Icu at 500 V AC 50/60 Hz (IEC 60947-2)
-
3 kA Icu at 690 V AC 50/60 Hz (IEC 60947-2)
-
-
Rated Service Short-Circuit Breaking Capacity (Ics):
-
100% at 230/240 V AC 50/60 Hz (IEC 60947-2)
-
50% at 400/415 V and 440 V AC 50/60 Hz (IEC 60947-2)
-
75% at 500 V and 690 V AC 50/60 Hz (IEC 60947-2)
-
-
Control Type: Push-button
-
Rated Current (In): 14 A
-
Thermal Protection Adjustment Range: 9–14 A (IEC 60947-2)
-
Magnetic Tripping Current: 253.4 A
-
Conventional Free Air Thermal Current (Ith): 14 A (IEC 60947-2)
-
Rated Operational Voltage (Ue): 690 V AC 50/60 Hz (IEC 60947-2)
-
Rated Insulation Voltage (Ui): 690 V AC 50/60 Hz (IEC 60947-2)
-
Rated Impulse Withstand Voltage (Uimp): 6 kV (IEC 60947-2)
-
Phase Failure Sensitivity: Yes (IEC 60947-4-1)
-
Suitability for Isolation: Yes (IEC 60947-1)
-
Power Dissipation per Pole: 2.5 W
-
Mechanical Durability: 100000 cycles
-
Electrical Durability: 100000 cycles for AC-3, AC-3e at 415 V
-
Rated Duty: Uninterrupted (IEC 60947-4-1)
-
Connections – Terminals:
-
Power circuit: Screw clamp terminal 2 cable(s) 1–6 mm² solid
-
Power circuit: Screw clamp terminal 2 cable(s) 1.5–6 mm² flexible without cable end
-
Power circuit: Screw clamp terminal 2 cable(s) 1–4 mm² flexible with cable end
-
-
Tightening Torque: 1.7 N.m on screw clamp terminal
-
Fixing Mode: 35 mm symmetrical DIN rail (clipped), Panel (screwed with adaptor plate)
-
Mounting Position: Horizontal, Vertical
-
Dimensions: 89 mm (H) x 45 mm (W) x 78.5 mm (D)
-
Weight: 0.26 kg
-
Colour: Dark grey
-
Standards:
-
EN/IEC 60947-2
-
EN/IEC 60947-4-1
-
UL 60947-4-1
-
CSA C22.2 No 60947-4-1
-
IEC/EN 60335-2-40:Annex JJ
-
IEC/EN 60335-1:Clause 30.2
-
-
Certifications: CCC, UL, CSA, EAC, ATEX, LROS (Lloyds register of shipping), BV, RINA, DNV-GL, UKCA
-
IK Degree of Protection: IK04
-
IP Degree of Protection: IP20 (IEC 60529)
-
Climatic Withstand: IACS E10 (damp heat)
-
Ambient Air Temperature for Operation: -20 to 60 °C
-
Ambient Air Temperature for Storage: -40 to 80 °C
-
Fire Resistance: 960 °C (IEC 60695-2-11)
-
Mechanical Robustness:
-
Shocks: 30 Gn for 11 ms
-
Vibrations: 5 Gn, 5-150 Hz
-
-
Operating Altitude: ≤2000 m