A9R71440 – SCHNEIDER Acti 9 iID – RCCB – 4P – 40A – 30mA – type AC
Product Name: Acti9 iID
Brand: Schneider Electric
Series: Acti9
Type: Residual Current Circuit Breaker (RCCB)
Device Short Name: iID
Poles: 4P
Neutral Position: Left
Rated Current ([In]): 40 A
Network Type: AC
Earth-Leakage Sensitivity: 30 mA
Earth-Leakage Protection Time Delay: Instantaneous
Earth-Leakage Protection Class: Type AC
Device Location in System: Outgoer
Network Frequency: 50/60 Hz
Rated Operational Voltage ([Ue]): 380…415 V AC, 50/60 Hz
Residual Current Tripping Technology: Voltage independent
Rated Breaking and Making Capacity: Idm 1500 A, Im 1500 A
Rated Conditional Short-Circuit Current: 10 kA
Rated Insulation Voltage ([Ui]): 500 V AC, 50/60 Hz
Rated Impulse Withstand Voltage ([Uimp]): 6 kV
Contact Position Indicator: Yes
Control Type: Toggle
Mounting Mode: Clip-on
Mounting Support: DIN rail
9 mm Pitches: 8
Dimensions (HxWxD): 91 x 72 x 73.5 mm
Net Weight: 0.37 kg
Colour: White
Mechanical Durability: 20,000 cycles
Electrical Durability: AC-1: 15,000 cycles
Locking Options Description: Padlocking device
Connections – Terminals:
-
Single terminal top or bottom 1…35 mm² rigid
-
Single terminal top or bottom 1…25 mm² flexible
-
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire Stripping Length: 14 mm (top or bottom connection)
Tightening Torque: 3.5 N·m (top or bottom)
Standards: EN/IEC 61008-1
Product Certifications: SNI
IP Degree of Protection: -
IP20 conforming to IEC 60529
-
IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree: 3
Electromagnetic Compatibility: 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Operating Temperature: -5…60 °C
Storage Temperature: -40…85 °C
Description
Product Name: Acti9 iID
Brand: Schneider Electric
Series: Acti9
Type: Residual Current Circuit Breaker (RCCB)
Device Short Name: iID
Poles: 4P
Neutral Position: Left
Rated Current ([In]): 40 A
Network Type: AC
Earth-Leakage Sensitivity: 30 mA
Earth-Leakage Protection Time Delay: Instantaneous
Earth-Leakage Protection Class: Type AC
Device Location in System: Outgoer
Network Frequency: 50/60 Hz
Rated Operational Voltage ([Ue]): 380…415 V AC, 50/60 Hz
Residual Current Tripping Technology: Voltage independent
Rated Breaking and Making Capacity: Idm 1500 A, Im 1500 A
Rated Conditional Short-Circuit Current: 10 kA
Rated Insulation Voltage ([Ui]): 500 V AC, 50/60 Hz
Rated Impulse Withstand Voltage ([Uimp]): 6 kV
Contact Position Indicator: Yes
Control Type: Toggle
Mounting Mode: Clip-on
Mounting Support: DIN rail
9 mm Pitches: 8
Dimensions (HxWxD): 91 x 72 x 73.5 mm
Net Weight: 0.37 kg
Colour: White
Mechanical Durability: 20,000 cycles
Electrical Durability: AC-1: 15,000 cycles
Locking Options Description: Padlocking device
Connections – Terminals:
-
Single terminal top or bottom 1…35 mm² rigid
-
Single terminal top or bottom 1…25 mm² flexible
-
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire Stripping Length: 14 mm (top or bottom connection)
Tightening Torque: 3.5 N·m (top or bottom)
Standards: EN/IEC 61008-1
Product Certifications: SNI
IP Degree of Protection: -
IP20 conforming to IEC 60529
-
IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree: 3
Electromagnetic Compatibility: 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Operating Temperature: -5…60 °C
Storage Temperature: -40…85 °C