Universe Middle East

CA2-KN22-M7 – SCHNEIDER TeSys K control relay – 2 NO + 2 NC – <= 690 V – 220…230 V AC coil

Product Name: TeSys CAK
Brand: Schneider Electric
Series: TeSys
Type: Control Relay
Device Short Name: CA2K
Contactor Application: Control Circuit
Utilisation Category: AC-15, DC-13
Pole Contact Composition: 2 NO + 2 NC
Rated Operational Voltage ([Ue]): ≤ 690 V, ≤ 400 Hz
Control Circuit Type: AC at 50/60 Hz
Control Circuit Voltage ([Uc]): 220…230 V AC, 50/60 Hz
Rated Thermal Current ([Ith]): 10 A (at 50 °C)
Rated Making Capacity (Irms): 110 A (IEC 60947)
Associated Fuse Rating:

  • 10 A gG (IEC 60947)

  • 10 A gG (VDE 0660)
    Rated Insulation Voltage ([Ui]):

  • 690 V (IEC 60947)

  • 750 V (VDE 0110 group C)

  • 690 V (BS 5424)

  • 600 V (CSA C22.2 No 14)
    Mounting Support: Rail, Plate
    Connections – Terminals:

  • 1× solid 1.5–4 mm²

  • 2× solid 1.5–4 mm²

  • 1× flexible 0.75–4 mm² with cable end

  • 2× flexible 0.75–4 mm² without cable end

  • 1× flexible 0.34–1.5 mm² with cable end

  • 2× flexible 0.34–1.5 mm² without cable end
    Tightening Torque: 1.3 N·m (flat Ø 6 mm / Philips No 2 / Pozidriv No 2)
    Control Circuit Voltage Limits:

  • Drop-out: 0.2…0.75 Uc (at <50 °C)

  • Operational: 0.8…1.15 Uc (at <50 °C)
    Operating Time:

  • 10–20 ms coil de-energisation and NO opening

  • 10–20 ms coil energisation and NO closing

  • 15–25 ms coil de-energisation and NC closing

  • 5–15 ms coil energisation and NC opening
    Mechanical Durability: 10 million cycles
    Maximum Operating Rate: 10,000 cycles/hour
    Immunity to Microbreaks: 2 ms
    Inrush Power: 30 VA (at 20 °C)
    Hold-in Power Consumption: 4.5 VA (at 20 °C)
    Heat Dissipation: 1.3 W
    Minimum Switching Voltage: 17 V
    Minimum Switching Current: 5 mA
    Non-Overlap Distance: 0.5 mm
    Insulation Resistance: > 10 MΩ
    Dimensions (HxWxD): 58 x 45 x 57 mm
    Net Weight: 0.18 kg
    Standards:

  • EN/IEC 60947-4-1

  • GB/T 14048.4

  • UL 60947-4-1

  • CSA C22.2 No 60947-4-1

  • JIS C8201-4-1
    Certifications: CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
    IP Degree of Protection: IP2X
    Protective Treatment: TC (IEC 60068)
    Operating Temperature: -25 to +50 °C
    Storage Temperature: -50 to +80 °C
    Operating Altitude: 2000 m (without derating)
    Flame Retardance:

  • V1 (UL 94)

  • Requirement 2 (NF F 16-101, NF F 16-102)
    Mechanical Robustness:

  • Vibrations (open): 2 Gn, 5–300 Hz (IEC 60068-2-6)

  • Vibrations (closed): 4 Gn, 5–300 Hz (IEC 60068-2-6)

  • Shocks (open): 10 Gn, 11 ms (IEC 60068-2-27)

  • Shocks (closed): 15 Gn, 11 ms (IEC 60068-2-27)

Description

Product Name: TeSys CAK
Brand: Schneider Electric
Series: TeSys
Type: Control Relay
Device Short Name: CA2K
Contactor Application: Control Circuit
Utilisation Category: AC-15, DC-13
Pole Contact Composition: 2 NO + 2 NC
Rated Operational Voltage ([Ue]): ≤ 690 V, ≤ 400 Hz
Control Circuit Type: AC at 50/60 Hz
Control Circuit Voltage ([Uc]): 220…230 V AC, 50/60 Hz
Rated Thermal Current ([Ith]): 10 A (at 50 °C)
Rated Making Capacity (Irms): 110 A (IEC 60947)
Associated Fuse Rating:

  • 10 A gG (IEC 60947)

  • 10 A gG (VDE 0660)
    Rated Insulation Voltage ([Ui]):

  • 690 V (IEC 60947)

  • 750 V (VDE 0110 group C)

  • 690 V (BS 5424)

  • 600 V (CSA C22.2 No 14)
    Mounting Support: Rail, Plate
    Connections – Terminals:

  • 1× solid 1.5–4 mm²

  • 2× solid 1.5–4 mm²

  • 1× flexible 0.75–4 mm² with cable end

  • 2× flexible 0.75–4 mm² without cable end

  • 1× flexible 0.34–1.5 mm² with cable end

  • 2× flexible 0.34–1.5 mm² without cable end
    Tightening Torque: 1.3 N·m (flat Ø 6 mm / Philips No 2 / Pozidriv No 2)
    Control Circuit Voltage Limits:

  • Drop-out: 0.2…0.75 Uc (at <50 °C)

  • Operational: 0.8…1.15 Uc (at <50 °C)
    Operating Time:

  • 10–20 ms coil de-energisation and NO opening

  • 10–20 ms coil energisation and NO closing

  • 15–25 ms coil de-energisation and NC closing

  • 5–15 ms coil energisation and NC opening
    Mechanical Durability: 10 million cycles
    Maximum Operating Rate: 10,000 cycles/hour
    Immunity to Microbreaks: 2 ms
    Inrush Power: 30 VA (at 20 °C)
    Hold-in Power Consumption: 4.5 VA (at 20 °C)
    Heat Dissipation: 1.3 W
    Minimum Switching Voltage: 17 V
    Minimum Switching Current: 5 mA
    Non-Overlap Distance: 0.5 mm
    Insulation Resistance: > 10 MΩ
    Dimensions (HxWxD): 58 x 45 x 57 mm
    Net Weight: 0.18 kg
    Standards:

  • EN/IEC 60947-4-1

  • GB/T 14048.4

  • UL 60947-4-1

  • CSA C22.2 No 60947-4-1

  • JIS C8201-4-1
    Certifications: CB Scheme, CCC, UL, CSA, EAC, CE, UKCA
    IP Degree of Protection: IP2X
    Protective Treatment: TC (IEC 60068)
    Operating Temperature: -25 to +50 °C
    Storage Temperature: -50 to +80 °C
    Operating Altitude: 2000 m (without derating)
    Flame Retardance:

  • V1 (UL 94)

  • Requirement 2 (NF F 16-101, NF F 16-102)
    Mechanical Robustness:

  • Vibrations (open): 2 Gn, 5–300 Hz (IEC 60068-2-6)

  • Vibrations (closed): 4 Gn, 5–300 Hz (IEC 60068-2-6)

  • Shocks (open): 10 Gn, 11 ms (IEC 60068-2-27)

  • Shocks (closed): 15 Gn, 11 ms (IEC 60068-2-27)