CAD32P7 – SCHNEIDER TeSys D control relay – 3 NO + 2 NC – <= 690 V – 230 V AC standard coil
Product Name: TeSys CAD
Brand: Schneider Electric
Series: TeSys / TeSys Deca
Type: Control Relay
Device Short Name: CAD
Contactor Application: Control Circuit
Utilisation Category: AC-14, AC-15, DC-13
Pole Contact Composition: 3 NO + 2 NC
Rated Operational Voltage ([Ue]): ≤ 690 V AC, 25…400 Hz
Control Circuit Type: AC at 50/60 Hz
Control Circuit Voltage ([Uc]): 230 V AC, 50/60 Hz
Impulse Withstand Voltage ([Uimp]): 6 kV (IEC 60947)
Rated Thermal Current ([Ith]): 10 A (at 60 °C)
Rated Making Capacity (Irms):
-
140 A AC (IEC 60947-5-1)
-
250 A DC (IEC 60947-5-1)
Rated Short-Time Withstand Current ([Icw]): -
100 A – 1 s
-
120 A – 500 ms
-
140 A – 100 ms
Associated Fuse Rating: 10 A gG (IEC 60947-5-1)
Rated Insulation Voltage ([Ui]): -
690 V (IEC 60947-5-1)
-
600 V (UL / CSA certified)
Mounting Support: Rail, Plate
Connections – Terminals: -
1× flexible 1…4 mm² (with/without cable end)
-
2× flexible 1…4 mm² (without cable end)
-
2× flexible 1…2.5 mm² (with cable end)
-
1× solid 1…4 mm² (without cable end)
-
2× solid 1…4 mm² (without cable end)
Tightening Torque: 1.2 N·m (Philips No 2 / Flat Ø 6 mm / Pozidriv No 2)
Control Circuit Voltage Limits: -
Drop-out: 0.3…0.6 Uc (-40…70 °C)
-
Operational:
-
0.8…1.1 Uc (AC 50 Hz, -40…60 °C)
-
0.85…1.1 Uc (AC 60 Hz, -40…60 °C)
-
1…1.1 Uc (AC 50/60 Hz, 60…70 °C)
Operating Time:
-
-
12–22 ms (NO closing)
-
4–12 ms (NO opening)
-
4–19 ms (NC opening)
-
6–17 ms (NC closing)
Mechanical Durability: 30 million cycles
Maximum Operating Rate: 180 cycles/min
Inrush Power: 70 VA (50 Hz, at 20 °C)
Hold-in Power Consumption: 8 VA (50 Hz, at 20 °C)
Minimum Switching Voltage: 17 V
Minimum Switching Current: 5 mA
Non-Overlap Time: 1.5 ms (energisation & de-energisation between NC and NO)
Insulation Resistance: > 10 MΩ
Mechanical Robustness: -
Shocks (open): 10 Gn, 11 ms (IEC 60068-2-27)
-
Shocks (closed): 15 Gn, 11 ms (IEC 60068-2-27)
-
Vibrations (open): 2 Gn, 5–300 Hz (IEC 60068-2-6)
-
Vibrations (closed): 4 Gn, 5–300 Hz (IEC 60068-2-6)
Dimensions (HxWxD): 77 x 45 x 84 mm
Net Weight: 0.58 kg
Standards: -
EN/IEC 60947-5-1
-
GB/T 14048.5
-
UL 60947-5-1
-
CSA C22.2 No 60947-5-1
-
JIS C8201-5-1
Certifications: CB, CCC, UL, CSA, EAC, CE, UKCA
IP Degree of Protection: IP2X (front face, VDE 0106)
Protective Treatment: TH (IEC 60068)
Operating Temperature: -40 to +60 °C (up to 70 °C with derating)
Storage Temperature: -60 to +80 °C
Operating Altitude: 0…3000 m
Description
Product Name: TeSys CAD
Brand: Schneider Electric
Series: TeSys / TeSys Deca
Type: Control Relay
Device Short Name: CAD
Contactor Application: Control Circuit
Utilisation Category: AC-14, AC-15, DC-13
Pole Contact Composition: 3 NO + 2 NC
Rated Operational Voltage ([Ue]): ≤ 690 V AC, 25…400 Hz
Control Circuit Type: AC at 50/60 Hz
Control Circuit Voltage ([Uc]): 230 V AC, 50/60 Hz
Impulse Withstand Voltage ([Uimp]): 6 kV (IEC 60947)
Rated Thermal Current ([Ith]): 10 A (at 60 °C)
Rated Making Capacity (Irms):
-
140 A AC (IEC 60947-5-1)
-
250 A DC (IEC 60947-5-1)
Rated Short-Time Withstand Current ([Icw]): -
100 A – 1 s
-
120 A – 500 ms
-
140 A – 100 ms
Associated Fuse Rating: 10 A gG (IEC 60947-5-1)
Rated Insulation Voltage ([Ui]): -
690 V (IEC 60947-5-1)
-
600 V (UL / CSA certified)
Mounting Support: Rail, Plate
Connections – Terminals: -
1× flexible 1…4 mm² (with/without cable end)
-
2× flexible 1…4 mm² (without cable end)
-
2× flexible 1…2.5 mm² (with cable end)
-
1× solid 1…4 mm² (without cable end)
-
2× solid 1…4 mm² (without cable end)
Tightening Torque: 1.2 N·m (Philips No 2 / Flat Ø 6 mm / Pozidriv No 2)
Control Circuit Voltage Limits: -
Drop-out: 0.3…0.6 Uc (-40…70 °C)
-
Operational:
-
0.8…1.1 Uc (AC 50 Hz, -40…60 °C)
-
0.85…1.1 Uc (AC 60 Hz, -40…60 °C)
-
1…1.1 Uc (AC 50/60 Hz, 60…70 °C)
Operating Time:
-
-
12–22 ms (NO closing)
-
4–12 ms (NO opening)
-
4–19 ms (NC opening)
-
6–17 ms (NC closing)
Mechanical Durability: 30 million cycles
Maximum Operating Rate: 180 cycles/min
Inrush Power: 70 VA (50 Hz, at 20 °C)
Hold-in Power Consumption: 8 VA (50 Hz, at 20 °C)
Minimum Switching Voltage: 17 V
Minimum Switching Current: 5 mA
Non-Overlap Time: 1.5 ms (energisation & de-energisation between NC and NO)
Insulation Resistance: > 10 MΩ
Mechanical Robustness: -
Shocks (open): 10 Gn, 11 ms (IEC 60068-2-27)
-
Shocks (closed): 15 Gn, 11 ms (IEC 60068-2-27)
-
Vibrations (open): 2 Gn, 5–300 Hz (IEC 60068-2-6)
-
Vibrations (closed): 4 Gn, 5–300 Hz (IEC 60068-2-6)
Dimensions (HxWxD): 77 x 45 x 84 mm
Net Weight: 0.58 kg
Standards: -
EN/IEC 60947-5-1
-
GB/T 14048.5
-
UL 60947-5-1
-
CSA C22.2 No 60947-5-1
-
JIS C8201-5-1
Certifications: CB, CCC, UL, CSA, EAC, CE, UKCA
IP Degree of Protection: IP2X (front face, VDE 0106)
Protective Treatment: TH (IEC 60068)
Operating Temperature: -40 to +60 °C (up to 70 °C with derating)
Storage Temperature: -60 to +80 °C
Operating Altitude: 0…3000 m
UME