Universe Middle East

CAD32P7 – SCHNEIDER TeSys D control relay – 3 NO + 2 NC – <= 690 V – 230 V AC standard coil

Product Name: TeSys CAD
Brand: Schneider Electric
Series: TeSys / TeSys Deca
Type: Control Relay
Device Short Name: CAD
Contactor Application: Control Circuit
Utilisation Category: AC-14, AC-15, DC-13
Pole Contact Composition: 3 NO + 2 NC
Rated Operational Voltage ([Ue]): ≤ 690 V AC, 25…400 Hz
Control Circuit Type: AC at 50/60 Hz
Control Circuit Voltage ([Uc]): 230 V AC, 50/60 Hz
Impulse Withstand Voltage ([Uimp]): 6 kV (IEC 60947)
Rated Thermal Current ([Ith]): 10 A (at 60 °C)
Rated Making Capacity (Irms):

  • 140 A AC (IEC 60947-5-1)

  • 250 A DC (IEC 60947-5-1)
    Rated Short-Time Withstand Current ([Icw]):

  • 100 A – 1 s

  • 120 A – 500 ms

  • 140 A – 100 ms
    Associated Fuse Rating: 10 A gG (IEC 60947-5-1)
    Rated Insulation Voltage ([Ui]):

  • 690 V (IEC 60947-5-1)

  • 600 V (UL / CSA certified)
    Mounting Support: Rail, Plate
    Connections – Terminals:

  • 1× flexible 1…4 mm² (with/without cable end)

  • 2× flexible 1…4 mm² (without cable end)

  • 2× flexible 1…2.5 mm² (with cable end)

  • 1× solid 1…4 mm² (without cable end)

  • 2× solid 1…4 mm² (without cable end)
    Tightening Torque: 1.2 N·m (Philips No 2 / Flat Ø 6 mm / Pozidriv No 2)
    Control Circuit Voltage Limits:

  • Drop-out: 0.3…0.6 Uc (-40…70 °C)

  • Operational:

    • 0.8…1.1 Uc (AC 50 Hz, -40…60 °C)

    • 0.85…1.1 Uc (AC 60 Hz, -40…60 °C)

    • 1…1.1 Uc (AC 50/60 Hz, 60…70 °C)
      Operating Time:

  • 12–22 ms (NO closing)

  • 4–12 ms (NO opening)

  • 4–19 ms (NC opening)

  • 6–17 ms (NC closing)
    Mechanical Durability: 30 million cycles
    Maximum Operating Rate: 180 cycles/min
    Inrush Power: 70 VA (50 Hz, at 20 °C)
    Hold-in Power Consumption: 8 VA (50 Hz, at 20 °C)
    Minimum Switching Voltage: 17 V
    Minimum Switching Current: 5 mA
    Non-Overlap Time: 1.5 ms (energisation & de-energisation between NC and NO)
    Insulation Resistance: > 10 MΩ
    Mechanical Robustness:

  • Shocks (open): 10 Gn, 11 ms (IEC 60068-2-27)

  • Shocks (closed): 15 Gn, 11 ms (IEC 60068-2-27)

  • Vibrations (open): 2 Gn, 5–300 Hz (IEC 60068-2-6)

  • Vibrations (closed): 4 Gn, 5–300 Hz (IEC 60068-2-6)
    Dimensions (HxWxD): 77 x 45 x 84 mm
    Net Weight: 0.58 kg
    Standards:

  • EN/IEC 60947-5-1

  • GB/T 14048.5

  • UL 60947-5-1

  • CSA C22.2 No 60947-5-1

  • JIS C8201-5-1
    Certifications: CB, CCC, UL, CSA, EAC, CE, UKCA
    IP Degree of Protection: IP2X (front face, VDE 0106)
    Protective Treatment: TH (IEC 60068)
    Operating Temperature: -40 to +60 °C (up to 70 °C with derating)
    Storage Temperature: -60 to +80 °C
    Operating Altitude: 0…3000 m

Description

Product Name: TeSys CAD
Brand: Schneider Electric
Series: TeSys / TeSys Deca
Type: Control Relay
Device Short Name: CAD
Contactor Application: Control Circuit
Utilisation Category: AC-14, AC-15, DC-13
Pole Contact Composition: 3 NO + 2 NC
Rated Operational Voltage ([Ue]): ≤ 690 V AC, 25…400 Hz
Control Circuit Type: AC at 50/60 Hz
Control Circuit Voltage ([Uc]): 230 V AC, 50/60 Hz
Impulse Withstand Voltage ([Uimp]): 6 kV (IEC 60947)
Rated Thermal Current ([Ith]): 10 A (at 60 °C)
Rated Making Capacity (Irms):

  • 140 A AC (IEC 60947-5-1)

  • 250 A DC (IEC 60947-5-1)
    Rated Short-Time Withstand Current ([Icw]):

  • 100 A – 1 s

  • 120 A – 500 ms

  • 140 A – 100 ms
    Associated Fuse Rating: 10 A gG (IEC 60947-5-1)
    Rated Insulation Voltage ([Ui]):

  • 690 V (IEC 60947-5-1)

  • 600 V (UL / CSA certified)
    Mounting Support: Rail, Plate
    Connections – Terminals:

  • 1× flexible 1…4 mm² (with/without cable end)

  • 2× flexible 1…4 mm² (without cable end)

  • 2× flexible 1…2.5 mm² (with cable end)

  • 1× solid 1…4 mm² (without cable end)

  • 2× solid 1…4 mm² (without cable end)
    Tightening Torque: 1.2 N·m (Philips No 2 / Flat Ø 6 mm / Pozidriv No 2)
    Control Circuit Voltage Limits:

  • Drop-out: 0.3…0.6 Uc (-40…70 °C)

  • Operational:

    • 0.8…1.1 Uc (AC 50 Hz, -40…60 °C)

    • 0.85…1.1 Uc (AC 60 Hz, -40…60 °C)

    • 1…1.1 Uc (AC 50/60 Hz, 60…70 °C)
      Operating Time:

  • 12–22 ms (NO closing)

  • 4–12 ms (NO opening)

  • 4–19 ms (NC opening)

  • 6–17 ms (NC closing)
    Mechanical Durability: 30 million cycles
    Maximum Operating Rate: 180 cycles/min
    Inrush Power: 70 VA (50 Hz, at 20 °C)
    Hold-in Power Consumption: 8 VA (50 Hz, at 20 °C)
    Minimum Switching Voltage: 17 V
    Minimum Switching Current: 5 mA
    Non-Overlap Time: 1.5 ms (energisation & de-energisation between NC and NO)
    Insulation Resistance: > 10 MΩ
    Mechanical Robustness:

  • Shocks (open): 10 Gn, 11 ms (IEC 60068-2-27)

  • Shocks (closed): 15 Gn, 11 ms (IEC 60068-2-27)

  • Vibrations (open): 2 Gn, 5–300 Hz (IEC 60068-2-6)

  • Vibrations (closed): 4 Gn, 5–300 Hz (IEC 60068-2-6)
    Dimensions (HxWxD): 77 x 45 x 84 mm
    Net Weight: 0.58 kg
    Standards:

  • EN/IEC 60947-5-1

  • GB/T 14048.5

  • UL 60947-5-1

  • CSA C22.2 No 60947-5-1

  • JIS C8201-5-1
    Certifications: CB, CCC, UL, CSA, EAC, CE, UKCA
    IP Degree of Protection: IP2X (front face, VDE 0106)
    Protective Treatment: TH (IEC 60068)
    Operating Temperature: -40 to +60 °C (up to 70 °C with derating)
    Storage Temperature: -60 to +80 °C
    Operating Altitude: 0…3000 m