LC1D65AE7 – SCHNEIDER TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 65 A – 48 V AC 50/60 Hz coil
-
Product Type: Contactor
-
Device Short Name: LC1D
-
Applications: Motor control, Resistive load
-
Utilization Categories: AC-1, AC-3, AC-3e, AC-4
-
Poles: 3P (3 NO)
-
Rated Operational Voltage (Ue): ≤690 V AC (25-400 Hz), ≤300 V DC
-
Rated Operational Current (Ie):
-
65 A (AC-3, AC-3e) at ≤440 V
-
80 A (AC-1) at ≤440 V
-
-
Control Circuit Voltage (Uc): 48 V AC 50/60 Hz
-
Motor Power (kW):
-
11 kW at 400 V (AC-4)
-
18.5 kW at 220-230 V (AC-3, AC-3e)
-
30 kW at 380-400 V (AC-3, AC-3e)
-
37 kW at 500-690 V (AC-3, AC-3e)
-
-
Motor Power (hp):
-
5 hp at 115 V (1-phase)
-
10 hp at 230/240 V (1-phase)
-
20 hp at 200-240 V (3-phase)
-
40 hp at 460/480 V (3-phase)
-
50 hp at 575/600 V (3-phase)
-
-
Conventional Free Air Thermal Current (Ith): 10 A (signaling), 80 A (power)
-
Rated Making Capacity (Irms):
-
1000 A at 440 V (power circuit)
-
140 A AC, 250 A DC (signaling circuit)
-
-
Rated Breaking Capacity: 1000 A at 440 V (power circuit)
-
Short-Time Withstand Current (Icw):
-
900 A (1 s), 640 A (10 s)
-
260 A (1 min), 110 A (10 min)
-
-
Fuse Rating: 10 A gG (signaling), 125 A gG (power)
-
Average Impedance: 1.5 mOhm (Ith 80 A, 50 Hz)
-
Power Dissipation per Pole:
-
9.6 W (AC-1)
-
6.3 W (AC-3, AC-3e)
-
-
Rated Insulation Voltage (Ui):
-
690 V (IEC 60947-4-1, signaling)
-
600 V (CSA, UL)
-
-
Impulse Withstand Voltage (Uimp): 6 kV
-
Mechanical Durability: 6 million cycles
-
Electrical Durability:
-
1.45 million cycles (65 A AC-3, AC-3e at ≤440 V)
-
1.4 million cycles (80 A AC-1 at ≤440 V)
-
-
Control Circuit: AC 50/60 Hz, 140-160 VA inrush, 13-15 VA hold-in
-
Connections – Terminals:
-
Control circuit: Screw clamp terminals (1-4 mm², flexible/solid)
-
Power circuit: Screw connection (1-35 mm², flexible/solid)
-
-
Tightening Torque:
-
Control circuit: 1.7 N.m (flat Ø 6 mm, Philips No 2, pozidriv No 2)
-
Power circuit: 5-8 N.m (EverLink BTR, hexagonal 4 mm, pozidriv No 2)
-
-
Auxiliary Contacts: 1 NO + 1 NC
-
Signaling Circuit Frequency: 25-400 Hz
-
Minimum Switching Voltage: 17 V (signaling circuit)
-
Minimum Switching Current: 5 mA (signaling circuit)
-
Insulation Resistance: > 10 MOhm (signaling circuit)
-
Non-Overlap Time:
-
1.5 ms on de-energisation (between NC and NO contact)
-
1.5 ms on energisation (between NC and NO contact)
-
-
Mounting Support: Plate, Rail
-
IP Degree of Protection: IP20 front face (IEC 60529)
-
Protective Treatment: TH (IEC 60068-2-30)
-
Climatic Withstand: IACS E10, IEC 60947-1 Annex Q category D (damp heat)
-
Operating Temperature: -40 to 60 °C (70 °C with derating)
-
Operating Altitude: 0-3000 m
-
Fire Resistance: 850 °C (IEC 60695-2-1)
-
Flame Retardance: V1 (UL 94)
-
Mechanical Robustness:
-
Vibrations: 2 Gn (open), 4 Gn (closed, 5-300 Hz)
-
Shocks: 10 Gn (open), 15 Gn (closed, 11 ms)
-
-
Dimensions: 122 mm (H) x 55 mm (W) x 120 mm (D)
-
Weight: 0.86 kg
-
Certifications: CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC
Description
-
Product Type: Contactor
-
Device Short Name: LC1D
-
Applications: Motor control, Resistive load
-
Utilization Categories: AC-1, AC-3, AC-3e, AC-4
-
Poles: 3P (3 NO)
-
Rated Operational Voltage (Ue): ≤690 V AC (25-400 Hz), ≤300 V DC
-
Rated Operational Current (Ie):
-
65 A (AC-3, AC-3e) at ≤440 V
-
80 A (AC-1) at ≤440 V
-
-
Control Circuit Voltage (Uc): 48 V AC 50/60 Hz
-
Motor Power (kW):
-
11 kW at 400 V (AC-4)
-
18.5 kW at 220-230 V (AC-3, AC-3e)
-
30 kW at 380-400 V (AC-3, AC-3e)
-
37 kW at 500-690 V (AC-3, AC-3e)
-
-
Motor Power (hp):
-
5 hp at 115 V (1-phase)
-
10 hp at 230/240 V (1-phase)
-
20 hp at 200-240 V (3-phase)
-
40 hp at 460/480 V (3-phase)
-
50 hp at 575/600 V (3-phase)
-
-
Conventional Free Air Thermal Current (Ith): 10 A (signaling), 80 A (power)
-
Rated Making Capacity (Irms):
-
1000 A at 440 V (power circuit)
-
140 A AC, 250 A DC (signaling circuit)
-
-
Rated Breaking Capacity: 1000 A at 440 V (power circuit)
-
Short-Time Withstand Current (Icw):
-
900 A (1 s), 640 A (10 s)
-
260 A (1 min), 110 A (10 min)
-
-
Fuse Rating: 10 A gG (signaling), 125 A gG (power)
-
Average Impedance: 1.5 mOhm (Ith 80 A, 50 Hz)
-
Power Dissipation per Pole:
-
9.6 W (AC-1)
-
6.3 W (AC-3, AC-3e)
-
-
Rated Insulation Voltage (Ui):
-
690 V (IEC 60947-4-1, signaling)
-
600 V (CSA, UL)
-
-
Impulse Withstand Voltage (Uimp): 6 kV
-
Mechanical Durability: 6 million cycles
-
Electrical Durability:
-
1.45 million cycles (65 A AC-3, AC-3e at ≤440 V)
-
1.4 million cycles (80 A AC-1 at ≤440 V)
-
-
Control Circuit: AC 50/60 Hz, 140-160 VA inrush, 13-15 VA hold-in
-
Connections – Terminals:
-
Control circuit: Screw clamp terminals (1-4 mm², flexible/solid)
-
Power circuit: Screw connection (1-35 mm², flexible/solid)
-
-
Tightening Torque:
-
Control circuit: 1.7 N.m (flat Ø 6 mm, Philips No 2, pozidriv No 2)
-
Power circuit: 5-8 N.m (EverLink BTR, hexagonal 4 mm, pozidriv No 2)
-
-
Auxiliary Contacts: 1 NO + 1 NC
-
Signaling Circuit Frequency: 25-400 Hz
-
Minimum Switching Voltage: 17 V (signaling circuit)
-
Minimum Switching Current: 5 mA (signaling circuit)
-
Insulation Resistance: > 10 MOhm (signaling circuit)
-
Non-Overlap Time:
-
1.5 ms on de-energisation (between NC and NO contact)
-
1.5 ms on energisation (between NC and NO contact)
-
-
Mounting Support: Plate, Rail
-
IP Degree of Protection: IP20 front face (IEC 60529)
-
Protective Treatment: TH (IEC 60068-2-30)
-
Climatic Withstand: IACS E10, IEC 60947-1 Annex Q category D (damp heat)
-
Operating Temperature: -40 to 60 °C (70 °C with derating)
-
Operating Altitude: 0-3000 m
-
Fire Resistance: 850 °C (IEC 60695-2-1)
-
Flame Retardance: V1 (UL 94)
-
Mechanical Robustness:
-
Vibrations: 2 Gn (open), 4 Gn (closed, 5-300 Hz)
-
Shocks: 10 Gn (open), 15 Gn (closed, 11 ms)
-
-
Dimensions: 122 mm (H) x 55 mm (W) x 120 mm (D)
-
Weight: 0.86 kg
-
Certifications: CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC