  • Product Type: Contactor

  • Device Short Name: LC1D

  • Applications: Motor control, Resistive load

  • Utilization Categories: AC-1, AC-3, AC-3e, AC-4

  • Poles: 3P (3 NO)

  • Rated Operational Voltage (Ue): ≤690 V AC (25-400 Hz), ≤300 V DC

  • Rated Operational Current (Ie):

    • 65 A (AC-3, AC-3e) at ≤440 V

    • 80 A (AC-1) at ≤440 V

  • Control Circuit Voltage (Uc): 48 V AC 50/60 Hz

  • Motor Power (kW):

    • 11 kW at 400 V (AC-4)

    • 18.5 kW at 220-230 V (AC-3, AC-3e)

    • 30 kW at 380-400 V (AC-3, AC-3e)

    • 37 kW at 500-690 V (AC-3, AC-3e)

  • Motor Power (hp):

    • 5 hp at 115 V (1-phase)

    • 10 hp at 230/240 V (1-phase)

    • 20 hp at 200-240 V (3-phase)

    • 40 hp at 460/480 V (3-phase)

    • 50 hp at 575/600 V (3-phase)

  • Conventional Free Air Thermal Current (Ith): 10 A (signaling), 80 A (power)

  • Rated Making Capacity (Irms):

    • 1000 A at 440 V (power circuit)

    • 140 A AC, 250 A DC (signaling circuit)

  • Rated Breaking Capacity: 1000 A at 440 V (power circuit)

  • Short-Time Withstand Current (Icw):

    • 900 A (1 s), 640 A (10 s)

    • 260 A (1 min), 110 A (10 min)

  • Fuse Rating: 10 A gG (signaling), 125 A gG (power)

  • Average Impedance: 1.5 mOhm (Ith 80 A, 50 Hz)

  • Power Dissipation per Pole:

    • 9.6 W (AC-1)

    • 6.3 W (AC-3, AC-3e)

  • Rated Insulation Voltage (Ui):

    • 690 V (IEC 60947-4-1, signaling)

    • 600 V (CSA, UL)

  • Impulse Withstand Voltage (Uimp): 6 kV

  • Mechanical Durability: 6 million cycles

  • Electrical Durability:

    • 1.45 million cycles (65 A AC-3, AC-3e at ≤440 V)

    • 1.4 million cycles (80 A AC-1 at ≤440 V)

  • Control Circuit: AC 50/60 Hz, 140-160 VA inrush, 13-15 VA hold-in

  • Connections – Terminals:

    • Control circuit: Screw clamp terminals (1-4 mm², flexible/solid)

    • Power circuit: Screw connection (1-35 mm², flexible/solid)

  • Tightening Torque:

    • Control circuit: 1.7 N.m (flat Ø 6 mm, Philips No 2, pozidriv No 2)

    • Power circuit: 5-8 N.m (EverLink BTR, hexagonal 4 mm, pozidriv No 2)

  • Auxiliary Contacts: 1 NO + 1 NC

  • Signaling Circuit Frequency: 25-400 Hz

  • Minimum Switching Voltage: 17 V (signaling circuit)

  • Minimum Switching Current: 5 mA (signaling circuit)

  • Insulation Resistance: > 10 MOhm (signaling circuit)

  • Non-Overlap Time:

    • 1.5 ms on de-energisation (between NC and NO contact)

    • 1.5 ms on energisation (between NC and NO contact)

  • Mounting Support: Plate, Rail

  • IP Degree of Protection: IP20 front face (IEC 60529)

  • Protective Treatment: TH (IEC 60068-2-30)

  • Climatic Withstand: IACS E10, IEC 60947-1 Annex Q category D (damp heat)

  • Operating Temperature: -40 to 60 °C (70 °C with derating)

  • Operating Altitude: 0-3000 m

  • Fire Resistance: 850 °C (IEC 60695-2-1)

  • Flame Retardance: V1 (UL 94)

  • Mechanical Robustness:

    • Vibrations: 2 Gn (open), 4 Gn (closed, 5-300 Hz)

    • Shocks: 10 Gn (open), 15 Gn (closed, 11 ms)

  • Dimensions: 122 mm (H) x 55 mm (W) x 120 mm (D)

  • Weight: 0.86 kg

  • Certifications: CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC

Description

  • Product Type: Contactor

  • Device Short Name: LC1D

  • Applications: Motor control, Resistive load

  • Utilization Categories: AC-1, AC-3, AC-3e, AC-4

  • Poles: 3P (3 NO)

  • Rated Operational Voltage (Ue): ≤690 V AC (25-400 Hz), ≤300 V DC

  • Rated Operational Current (Ie):

    • 65 A (AC-3, AC-3e) at ≤440 V

    • 80 A (AC-1) at ≤440 V

  • Control Circuit Voltage (Uc): 48 V AC 50/60 Hz

  • Motor Power (kW):

    • 11 kW at 400 V (AC-4)

    • 18.5 kW at 220-230 V (AC-3, AC-3e)

    • 30 kW at 380-400 V (AC-3, AC-3e)

    • 37 kW at 500-690 V (AC-3, AC-3e)

  • Motor Power (hp):

    • 5 hp at 115 V (1-phase)

    • 10 hp at 230/240 V (1-phase)

    • 20 hp at 200-240 V (3-phase)

    • 40 hp at 460/480 V (3-phase)

    • 50 hp at 575/600 V (3-phase)

  • Conventional Free Air Thermal Current (Ith): 10 A (signaling), 80 A (power)

  • Rated Making Capacity (Irms):

    • 1000 A at 440 V (power circuit)

    • 140 A AC, 250 A DC (signaling circuit)

  • Rated Breaking Capacity: 1000 A at 440 V (power circuit)

  • Short-Time Withstand Current (Icw):

    • 900 A (1 s), 640 A (10 s)

    • 260 A (1 min), 110 A (10 min)

  • Fuse Rating: 10 A gG (signaling), 125 A gG (power)

  • Average Impedance: 1.5 mOhm (Ith 80 A, 50 Hz)

  • Power Dissipation per Pole:

    • 9.6 W (AC-1)

    • 6.3 W (AC-3, AC-3e)

  • Rated Insulation Voltage (Ui):

    • 690 V (IEC 60947-4-1, signaling)

    • 600 V (CSA, UL)

  • Impulse Withstand Voltage (Uimp): 6 kV

  • Mechanical Durability: 6 million cycles

  • Electrical Durability:

    • 1.45 million cycles (65 A AC-3, AC-3e at ≤440 V)

    • 1.4 million cycles (80 A AC-1 at ≤440 V)

  • Control Circuit: AC 50/60 Hz, 140-160 VA inrush, 13-15 VA hold-in

  • Connections – Terminals:

    • Control circuit: Screw clamp terminals (1-4 mm², flexible/solid)

    • Power circuit: Screw connection (1-35 mm², flexible/solid)

  • Tightening Torque:

    • Control circuit: 1.7 N.m (flat Ø 6 mm, Philips No 2, pozidriv No 2)

    • Power circuit: 5-8 N.m (EverLink BTR, hexagonal 4 mm, pozidriv No 2)

  • Auxiliary Contacts: 1 NO + 1 NC

  • Signaling Circuit Frequency: 25-400 Hz

  • Minimum Switching Voltage: 17 V (signaling circuit)

  • Minimum Switching Current: 5 mA (signaling circuit)

  • Insulation Resistance: > 10 MOhm (signaling circuit)

  • Non-Overlap Time:

    • 1.5 ms on de-energisation (between NC and NO contact)

    • 1.5 ms on energisation (between NC and NO contact)

  • Mounting Support: Plate, Rail

  • IP Degree of Protection: IP20 front face (IEC 60529)

  • Protective Treatment: TH (IEC 60068-2-30)

  • Climatic Withstand: IACS E10, IEC 60947-1 Annex Q category D (damp heat)

  • Operating Temperature: -40 to 60 °C (70 °C with derating)

  • Operating Altitude: 0-3000 m

  • Fire Resistance: 850 °C (IEC 60695-2-1)

  • Flame Retardance: V1 (UL 94)

  • Mechanical Robustness:

    • Vibrations: 2 Gn (open), 4 Gn (closed, 5-300 Hz)

    • Shocks: 10 Gn (open), 15 Gn (closed, 11 ms)

  • Dimensions: 122 mm (H) x 55 mm (W) x 120 mm (D)

  • Weight: 0.86 kg

  • Certifications: CCC, UL, CB Scheme, CSA, CE, UKCA, Marine, EAC